Sign In | Join Free | My himfr.com
Home > MID Approved Energy Meter >

MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A

shanghai fangqiu electric co.,ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A from wholesalers
     
    Buy cheap MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A from wholesalers
    • Buy cheap MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A from wholesalers
    • Buy cheap MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A from wholesalers
    • Buy cheap MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A from wholesalers
    • Buy cheap MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A from wholesalers
    • Buy cheap MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A from wholesalers
    • Buy cheap MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A from wholesalers

    MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A

    Ask Lasest Price
    Brand Name : Fineco
    Model Number : EM737 CT
    Price : $50.00/units
    • Product Details
    • Company Profile

    MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A

    EM737 CT 3*230/400V 10(100)A

    MID approved three-phase modbus energy meter

    MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A Benefits and Main Features

    • Three phase kWh metering ,digital energy meter
    • Standard DIN rail Format (DIN43880)
    • EN50470-3 Class B.
    • Import &Export active energy
    • Import &Export reactive energy
    • Instant Volt, Amp, Power factor, Frequency, Active power, Reactive power, Apparent power
    • Isolate pulse output and IR (DIN43864)
    • LCD display, 6 integer 2 decimal
    • Large clear backlight display
    • Internal transformer
    • 27 CT rate can be selected
    • Optional single-phase model
    • RS485 communication port, modbus protocol
    • IR port
    • Program by button on the nameplate
    • Memory back-up (EEprom)
    • 7 DIN modules
    • MID approved
    • The meter is intended to be installed in a Mechanical Environment ‘M1’, with Shock and Vibrations of low significance, as per 2004/22/EC Directive and should be installed in Electromagnetic Environment ‘E2’, as per 2004/22/EC Directive

    Meter specification


    CT connected meter

    Voltage(v)

    3×230/400V

    Operational voltage

    (70-130)%Un

    Current(A)

    - Iref

    1.5A

    -Itr

    0.15A

    -Imax

    6A

    -Imin

    0.075A

    -Ist

    3mA

    Power consumption of current circuits(VA)

    < 0.01

    Power consumption of voltage circuits(W)

    < 1.3W

    General data

    Frequency (Hz)

    50

    Memory back-up

    EEprom

    Environment resistance to heat and fire

    Terminal 960°C

    Cover 650°C

    upper

    ABS+PC

    lower

    ABS+PC

    Pulse output

    Pulse width(ms)

    80

    Pulse constant(imp/kWh)

    6400

    LED constant

    6400

    Width (mm)

    126

    Height (mm)

    104.5

    Depth (mm)

    60


    Main function

    Measuring Function

    On the EM737’S front panel, there are three LED, active/reactive energy pulse light, and alarm indicator lights .

    Meter can measure import & export active energy , import & export reactive energy. The measurement type can be set MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A


    Display function

    Smart meter have two status: cycle display status andbutton press display .When pressing the button, User can set according their request. Button press will Backlight the LCD. Display cycle can be set within 5~20 seconds, The default is 5 seconds


    Electricity parameters measurement and monitoring

    Measure record and display voltage, current, power and power factors. error is not more than ±1%.


    Communication Function

    With an infrared COM and a RS485 COM. Its physical layers are independent with each other. One communication channel will not be affected by the other one. The meter can realize data acquisition, broadcast time setting, read, program and manage through hand-held terminals, data acquisition terminal, test equipments and computers. Communication protocols fit Modbus RTU standard.MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A


    MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A

    Using communication function , the smart meter can connection to the Fineco Cloud.The reading can be viewed through the web browse at any time.

    MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A


    Alarm function

    When the meter connect wire wrong example: current reverse, lost phase and reversed phase sequence , the meter will display , the ALARM led will be on.


    Pulse output function

    Smart meter is equipped with a pulse output which is fully separated from the inside circuit. That generates pulses in proportion to the measured energy .include the testing pulse output of active energy and reactive energy. 8/ 11 Test pulse output contact (P+/P-),9/ 11 Test pulse output contact (Q+/Q-)


    Certification:

    MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A


    MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A

    MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A


    Related products

    MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A


    Company Information

    MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A

    Quality MID Approved Three-Phase Modbus Energy Meter EM737 CT 3*230/400V 10 100 A for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: shanghai fangqiu electric co.,ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)